Domekt R 300 V M5 Original filter Komfovent® - 1
  • On sale!
  • -7%

Domekt R 300 V M5 Original filter

Reference: 774100137

€16.95
€15.77 Save 7%
delivery in 1-3 working days

Ex Tax: €13.03

Filter dimensions 290x205x46
Class EN779 M5
Class ISO16890 ePM10 50%
Protection level Average: medium-sized solid particles, dust, fluff, pollen, mold spores.
Quantity of filters 1
Advantages check Genuine (original) filter.
check Low airflow resistance: longer servicing term, lower energy consumption.
check Made in the EU.
check Premium class certified synthetic filtering material (SANDLER AG, Germany)

Volume discounts

Quantity Price You Save
3 €14.98 Up to €2.36
5 €14.19 Up to €7.88
10 €13.40 Up to €23.65
Quantity
In stock

Amount left to get free delivery: €36.00

                                              

774100137

Data sheet

Manufacturer of MVHR
Komfovent
Manufacturer
Original
Model
Domekt R
Model size
300
Air handling unit
Domekt R 300 V
Filter dimensions
290x205x46
Class EN779
M5
Class ISO16890
ePM10 50%
Protection level
Average: medium-sized solid particles, dust, fluff, pollen, mold spores.
Quantity of filters
1
Advantages
Genuine (original) filter.
Low airflow resistance: longer servicing term, lower energy consumption.
Made in the EU.
Premium class certified synthetic filtering material (SANDLER AG, Germany)
Manufacturer product number
774100137
Google category ID
3573
Product type
Filters for Air Handling Units

Genuine (original) M5 class filter. Classification according to ISO 16890: ePM10 50%. Suitable for extract and supply air filtration.

M5 class filters are used not only to protect the air handling unit and ventilation system from contamination, but also efficiently capture pollen, mold spores, and other allergens.  

Pressure drops in M5 filters are much lower than in F7 class filters. Therefore, M5 filters serve longer and are the best option even in areas with moderate pollution by PM10-size particles, like small towns, suburban areas, etc. 

The filtering efficiency of the M5 filter:

  • Coarse particles: >90% (dust, pollen)
  • PM10 particles: >50% (mold spores, animal dander)
  • PM2.5 particles: <20% (combustion particles)
  • PM1 particles: - (solid smog particles, virus carriers)

Filter construction:

  • Type: MPL (deep pleat). Extra-large filtration surface.
  • Filtering material: premium synthetic fiber.
  • Moisture-resistant cardboard or synthetic frame (depends on filter). Operates even at 100% RH. Opposite to metal or plastic frames, such filters adapt to the construction of filter holders. Thus, ensuring airtightness and do not damage AHU's construction. 
  • Filtering material corresponds to hygienic requirements (resistant to microorganisms' growth).

Advantages with other filters

  • Moisture-resistant frame, which works at 100% relative humidity. Designed to wet European climate. 
  • Airtight construction. Material is firmly glued to the frame. Hazardous particles do pass through the frame and material connection. 
  • Adapts to the construction of the equipment. As in the original filters synthetic or cardboard frame adapts to ventilation unit construction and does not damage it (especially EPP casing).
  • Filters made in the EU and tested according to ISO16890.  Cheap filters from China mostly are not tested and only theoretical filtering efficiencies are being provided. 
  • Filters are made from premium synthetic material. Unlike glass fiber, it is safe and not fragile. 

Replacement period: The replacement period depends on outdoor air contamination. Expected service term: 5-7 months. Do not wash or clean. Single-use only. 

Additional information:

  • Packing: Filters are packed in plastic film suitable for long-term storage.
  • Warranty: 2-year storage warranty if kept in proper condition and package.
  • Storage conditions: internal premises, RH<60%, low dustiness.
  • Made in the EU.

For an extra discount for higher quantities of filters please contact us directly.

General recommendations:

  • Filter contamination is monitored by the timer in the control device. Filter change alerts are shown in the control panel or the mobile application. 
  • Filter change indication works as a reminder. AHU will operate despite this warning. 
  • The replacement period depends on outdoor air contamination. You might be needed to replace filters up to 1.5-2 times more frequently, if you live near intense traffic roads, paved roads, construction sites, industrial areas, working fields, etc. 
  • Most manufacturers recommend changing filters at least twice a year: before and after the heating season. 
  • Recommended replacement terms: activated carbon filters: up to 3 months, F7 filter - 4-6 months, M5, G4 filters - 5-8 months. Energy-efficient filters last 1.3-2 times longer. F7, F8, and F9 filter servicing terms can be prolonged up to 2-3 months if an additional G4 class prefilter is being used in the ventilation system. 
  • The extracted air filter can be changed less frequently, if you are using efficient F7, F8, F9, or activated carbon filters for outdoor air filtration.  
  • Panel/pocket filters are single-use only. Vacuuming or cleaning will not provide the desired effect, only can damage the filter. Efficient filtering material captures small particles inside and it clogs the filter. 
  • Wire-framed filters and filtering materials can be vacuumed up to 3 times before replacement if the user manual allows it.
  • Keep the flanges of your new ventilation unit covered before its first launch, in order to avoid quick filter contamination. 

Universal instruction

  • Always check the user manual if changing filters for the first time. 
  • Before proceeding turn off the ventilation unit and wait until the fan stops rotating completely.
  • Remove the front cover or filter cover.
  • Remove old filters.
  • Clean the unit with a vacuum cleaner and clean filter holders with wet wipes.
  • It is recommended to check other AHU components also: rotor belt, heat exchanger, fan impellers, etc. And clean if necessary.
  • Check the airflow direction before placing the new filters. Filters have airflow arrows on the labels they must match airflow direction. Usually, filters are installed before the heat exchanger, so arrows must point toward the center. However, if 3 filters are used there might be exceptions: if F7 or F8 filter is on the opposite side of the heat exchanger from that G4 filter, the airflow must point away from the heat exchanger. Most manufacturers placed arrows on the ventilation unit in order to install filters correctly. If filters are installed in the opposite direction, pressure resistance may increase up to 15%.
  • If you have filters of different efficiencies, e.g. F7 and G4. F7 filters must be installed on the Outdoor air side, and G4 on the Extract air side. The manufacturer marks them nearby duct connection flanges. Usually, the outdoor air duct is insulated and the extract air duct is not. Also, you may check the user manual, but pay attention, that it might be the right and left versions on the unit.
  • After installing new clean filters put the cover back. Then turn the device on.
  • Also, you will need to restart the filter timer on the control device according to user manual instructions.

Do not operate the air handling unit without filters, it will clog your heat exchanger and contaminate the ventilation system. Also, your warranty will be void.

Contaminated filters provide higher airflow resistance, and it lead to lower airflow volumes, higher energy consumption, and higher sound emissions. Change them on time and the ventilation unit will operate longer.

We are keen to supply you with top-quality air filters for the perfect indoor climate at the best price. We offer more than just a filter:

  • Experience and professional support: our consultants have long-term experience in HVAC production and service fields.
  • Wide range:  multiple options, including activated carbon, and energy-efficient filters for the most AHUs.
  • Fast delivery: over 40000 filters in our production warehouse are ready to be shipped next/same working day.
  • Quality materials:  filtering materials are made by leading companies such as SANDLER AG and have high efficiency and dust-holding capacity.
  • Top quality: all the filters, including of G4 class are glued to the frame to ensure maximum airtightness. 
  • Low prices: due to the short supply chain and high volumes we offer probably the best prices for quality filters in the EU.
  • Made in the EU. Over 85% percent of the ventilation filters sold in the EU are made in China from low-quality materials. 
  • Tested efficiency. Filters are tested in an accredited laboratory in Germany according to ISO16890 standards 

         

Filter is a replaceable component of any ventilation equipment therefore sustainable production and logistics play a key role.

Production:

  • High-quality 3-ply filtering material has a larger dust-holding capacity. Therefore, filters serve longer, and less material can be used in production.
  • We do not use glass fiber material in filters. Glass fiber is fragile, potentially hazardous, and non-recyclable.
  • Panel filter frames are made of moisture-resistant cardboard. The supplier uses the maximum possible amount of recycled cardboard production.
  • Energy in production plants comes from renewable sources.
  • Filter frames for certain Zehnder ComfoAir models are made of eco plastic with organic materials content of more than 80%.
  • Offer filter options made of energy-efficient materials, with 1.3-2 times longer replacement periods.
  • Due to patented technology, we use 30-50% less glue than used in other alternative filters.

 

Shorter delivery distance:

  • Materials for production are made by factories located in the EU countries.
  • Filers made in the EU (more than 80% of filters in the market are made in China or other Asian countries).
  • We deliver directly from the production warehouse.

We are constantly searching the ways to provide more sustainability to your filter!

PFAS chemicals have been used in a wide range of products since the 1940s. PFAS can migrate into soil, water and air during production or use. Most of these chemicals are practically non-degradable. A number of scientific studies indicate that PFAS chemicals may pose a risk to human and animal health.

Major health risks

Main products containing PFAS

CleanFilter filters are manufactured of certified high quality synthetic filtering material free of PFAS compounds.

  • Healthier indoor air. PFAS chemicals do not get into the air and do not spread throughout your rooms. 
  • Complies with the latest standards. The filters comply with current safety requirements and pending legislation relating to PFAS materials.
  • Excellent performance. Synthetic filter material offers durability and performance without the need for additional additives.
  • Environmental protection. By choosing PFAS-free filters, you are contributing to reducing environmental pollution and protecting public health.
Based on 0 reviews - 0 1 2 3 4 0/5

4 other products in the same category: